Up all
Pack up all
-
Technical Feature
OPERATION:
The valve will allow flow from the higher pressure of port ① or ③ to the port ② . The
valve is commonly used to direct oil from the pressure side of a bidirectional hydraulic
motor to a pressure-released hydraulic brake. -
PerformanceCurves
-
Technical Data
350barSee PRESSURE DROP VS.FLOW graph.Refer to "Cleanliness of Hydraulic Fluid"5 drops/min Max at 350bar.-40°F to +250°F(-40°C to +120°C)Mineral-based fluids with viscosities of 7.4 to 420 cSt.Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES