LACR.M18

PDF Download

Description

A cartridge-style direct-acting poppet-type anti-cavitation relief valve

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    Flow is free from ① to ② until pressure increases to meet the selected valve setting, allowing
    relief flow through port
    ① to tank. This valve combines the typical function of shock relief valve
    (direct acting) and anticavitation function through the check valve. The direct action and the
    specific design allow a very fast opening and closing.
    Note: to obtain a good leak proof performance coin the cavity seat using a loose valve seat as a
    coning tool.
    Torque to be applied :4.5 ± 2 Nm.

  • PerformanceCurves

    ll.png

  • Technical Data

    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    Rexroth-730
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Max.Operating Pressure
    380Bar
    Max.Flow
    60 l/min.
    Standard Spring Ranges
    10 to 70 bar;
    70 to 120bar;
    120 to 200bar;
    200 to 270 bar;
    270 to 320 bar;
    320 to 380 bar;
    Temperature
    -40°F to +250°F(-40°C to +120°C)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    Steel & Ductile iron rated to 350bar
  • File Download

    PDF File
  • ACCESSORIES

Contact Us