Description

A cartridge-style direct-acting poppet-type relief valve

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    Flow is blocked from ① to ② until pressure increases to meet the selected valve
    setting, lifting the poppet from its seat and allowing relief flow through
    ② to tank.
    Pressure at
    ② is additive to the relief setting of the valve. The unique poppet design
    provides enhanced stability at all flows and pressures.

  • PerformanceCurves

    曲线.png

  • Technical Data

    Operating Pressure
    400Bar
    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    Rexroth - DBD -10K
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Internal Leakage
    5 drops/min. max. to 80% of nominal setting
    Reseat Pressure
    80% of crack pressure (crack pressure at 0.95 lpm /0.25 gpm)
    Standard Spring Ranges
    25 to 400 bar; preset 200 bar
    Temperature
    -40°F to +250°F(-40°C to +120°C)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    Steel & Ductile iron rated to 350bar