Up all
Pack up all
-
Technical Feature
OPERATION:
In the dividing mode, the valve will divert input flow from port "P" to ports" Z1"and"Z2"
based on the ratio specified, regardless of operating pressure. When the flow direction is
reversed the valve will combine flows from"Z1 "and" Z2"to port "P". -
Technical Data
345BarRefer to "Cleanliness of Hydraulic Fluid"A: 1.4-16.6 l/min.; B: 1.8-26 l/min.; C: 7.3-36.5 l/min.±1% at max. input flow
±3% at min. input flow
Pressure drop at maximum rated input flow 30 bar
Pressure drop at minimum rated input flow 7 bar-40°F to +250°F(-40°C to +120°C)Mineral-based fluids with viscosities of 7.4 to 420 cSt.Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES