This valve allows free flow from port ① to port ② and blocks flow from port ② to port ① or holding a load. Flow will be allowed from port ② to port ① when pressure is applied to pilot ③ .
This pilot operated check valve has a 45:1 pilot ratio, meaning that it takes at least 1/45 of the load pressure held at port ② required at pilot ③ to open the valve. -
Technical Data
100 l/minRefer to "Cleanliness of Hydraulic Fluid"350Bar2 drops/min max. at 350 bar0.5bar45:1-40°F to +250°F(-40°C to +120°C)Mineral-based fluids with viscosities of 7.4 to 420 cSt.Steel & Ductile iron rated to 350bar -