Cartridge valve
Flow Valves
- Flow Control Valves
- Needle Valves Flow Control Valves Dividers/Combiners Other
Up all
Pack up all
-
Technical Feature
OPERATION
The valve maintains a constant flow rate from ③ regardless of load pressure changes
in the system downstream of ③, or in the bypass leg at ② .The valve will pressure
compensate once a minimum pressure drop (determined by the fixed spring setting) is
achieved from ① to ③ . Bypass port ② may be fully pressurized. Flow out of priority
port ③ may vary based on input flow amount, particularly with lower temperatures and
increased fluid viscosities -
PerformanceCurves
-
Technical Data
Flow0.4 to 5.9 l/min. setting ±15%
6 to 22.7 l/min. setting ±10%Cavity10-3FiltrationRefer to "Cleanliness of Hydraulic Fluid"Max.Operating Pressure240barTemperature-40ºF to +250ºF(-40ºC to +120ºC)FluidsMineral-based fluids with viscosities of 7.4 to 420 cSt.Body Material6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES
Accessories