- 4-Way 2-Position
- 2-Way 2-Position 3-Way 2-Position 4-Way 2-Position 4-Way 3-Position 5-Way 3-Position
Up all
Pack up all
-
Technical Feature
OPERATION:
When de-energized, the valve allows flow from ③ to ④ or from ④ to ③ and
from ② to ① or from ① to ② . When energized, the cartridge's spool shifts to allow
flow from ③ to ② or from ② to ③ and from ④ to ① or from ① to ④ .Operation of Manual Override Option:
M: To override, push button in to activate. To return to normal valve function, release
button.
MK: To override, twist clockwise 2 turns. In this position, the valve will allow
flow ③ to ② and from ④ to ① . To return to normal operation, twist counterclockwise
2 turns. -
PerformanceCurves
-
Technical Data
Operating Pressure350BarFlowSee PRESSURE DROP VS.FLOW graph.CavityHYDAC 08140FiltrationRefer to "Cleanliness of Hydraulic Fluid"Internal Leakage82cc/min. max. at 350barTemperature-40°F to +212°F(-40°C to +100°C)Coil Duty RatingContinuous from 85% to 115% of nominal voltageFluidsMineral-based fluids with viscosities of 7.4 to 420 cSt.Body MaterialSteel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES
CoilAccessories