OPERATION:
The valve maintains a constant flow within specified accuracies from inlet to
outlet regardless of downstream load pressure. When flow produces a minimum
predetermined pressure differential across the compensator spool control orifice, the
spool shifts against the spring force to throttle the flow and maintain the flow setting. In
the reverse direction the spool shifts to permit free flow. -
PerformanceCurves
-
Technical Data
Operating Pressure207barFlowSee PRESSURE DROP VS.FLOW graph.Cavity14SFiltrationRefer to "Cleanliness of Hydraulic Fluid"Flow Setting8 gpm (30.3 l/min.)
12 gpm(45.4 l/min.)
17 gpm(64.3 l/min.)
24 gpm(90.8 l/min.)Flow Maintenance Accuracyall valves: +5% -15%Temperature-40°F to +250°F(-40°C to +120°C)FluidsMineral-based fluids with viscosities of 7.4 to 420 cSt.Body Material6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -