Up all
Pack up all
-
Technical Feature
OPERATION:
The valve allows flow from ② to ① , while normally blocking flow from ① to ② . Flow will be allowed from ① to ② when sufficient pressure is applied at port “P”.
The cartridge has a 3:1 pilot ratio, meaning that at least one-third of the load pressure held at ① is required at “P” to open the valve.
-
PerformanceCurves
-
Technical Data
350BarSee PRESSURE DROP VS.FLOW graph.10-2Refer to "Cleanliness of Hydraulic Fluid"2 drops/min. max. at 350bar2.1=2.1bar
4.2=4.2bar
8.4=8.4bar3:1-40°F to +250°F(-40°C to +120°C)Mineral-based fluids with viscosities of 7.4 to 420 cSt.Steel & Ductile iron rated to 350bar -
File Download
PDF File -