OPERATION:
On no remote pilot signal at ① ,the valve allows flow from ③ to ② bi-directionally, while
flow is blocked at ④ ,spring chamber vent-to-atmosphere, which is internally 0-ring
sealed from the cartridge flow paths.
On remote pilot signal at ①, the valve shifts to open from ③ to ④,while blocking
flow at ②.
Because of the vented spring chamber, the cartridge may be fully pressurized at any
port without affecting required pilot pressure.
-
PerformanceCurves
-
Technical Data
Operating Pressure250BarFlowSee PRESSURE DROP VS.FLOW graph.Cavity10-4FiltrationRefer to "Cleanliness of Hydraulic Fluid"Internal Leakage82 cc/min. max. at 250 barPilot Pressure RequiredTo Spool Crossover 7.6 bar(110psi)
To Full Spool Shift 8.6 bar(125psi)Temperature-40°F to +250°F(-40°C to +120°C)FluidsMineral-based fluids with viscosities of 7.4 to 420 cSt.Body Material6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -