Technical Feature
OPERATION:
On no remote pilot signal at ①,the valve allows flow from ③to ② bi-directionally, while flow is blocked at ④ ,spring chamber vent-to-atmosphere, which is internally 0-ring sealed from the cartridge flow paths.On remote pilot signal at ①, the valve shifts to open from ③ to ④,while blocking flow at ②.Because of the vented spring chamber, the cartridge may be fully pressurized at any port without affecting required pilot pressure.
-
PerformanceCurves
-
Technical Data
250BarSee PRESSURE DROP VS.FLOW graph.10-4Refer to "Cleanliness of Hydraulic Fluid"82 cc/min. max. at 250 barTo Spool Crossover 7.6 bar(110psi)
To Full Spool Shift 8.6 bar(125psi)-40°F to +250°F(-40°C to +120°C)Mineral-based fluids with viscosities of 7.4 to 420 cSt.6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -