LPRPS2-10

PDF Download

Description

A cartridge-style pilot-operated pressure reducing/ relieving valve

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    In its steady state, the valve allows flow to pass from to ①, with the spring
    chamber constantly drained at
    ③. On attainment of a pre-determined pressure at ,
    the cartridge shifts to restrict input flow at
    , thereby regulating pressure at . In this
    mode, the valve will also relieve
    to over the reducing setting.


  • PerformanceCurves

    4.png

  • Technical Data

    Operating Pressure
    350Bar
    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    10-3
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Internal Leakage
    from②to③ 82 cc/min. max. at 85% of crack pressure
    Standard Spring Ranges
    3.45-103 bar, preset: 52bar
    3.45-207 bar, preset:103bar
    3.45-350 bar, preset:175bar
    Temperature
    -40°F to +250°F(-40°C to +120°C)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    Steel & Ductile iron rated to 350bar
  • File Download

    PDF File
  • ACCESSORIES

    Accessories
Contact Us