Up all
Pack up all
-
Technical Feature
OPERATION:
In its steady state, the valve blocks flow from ③ to ② . On attainment of a predetermined
pressure at ①,the cartridge shifts to open ③ to ② . Since the spring
chamber is vented at ②,back pressure at ② will directly (1:1)affect the valve’s
setting.
-
PerformanceCurves
-
Technical Data
Operating Pressure207BarFlowSee PRESSURE DROP VS.FLOW graph.Cavity10-3FiltrationRefer to "Cleanliness of Hydraulic Fluid"Internal Leakage82 cc/min. max. to 90% of nominal settingStandard Spring Ranges5.5-27.6 bar, preset:13.8bar
13.8-55.2 bar, preset:27.6bar
20.7- 103 bar, preset:51.5bar
28- 145 bar, preset:72.5barTemperature-40°F to +250°F(-40°C to +120°C)FluidsMineral-based fluids with viscosities of 7.4 to 420 cSt.Body Material6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES