Description

A cartridge-style non-adjustable pressure-compensated flow control valve

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    The valve maintains a constant flow rate out of regardless of load pressure changes
    in the circuit downstream of
    ②. The fixed control orifice is factory preset to customer
    flow specification.
    The valve begins to respond to load changes when the flow through the valve creates
    a pressure differential across the control orifice greater than 5.5 bar, with accurate flow
    maintenance from 7.6 to 240 bar. Reverse flow(
    to )returns through the control
    orifice and is non-compensated.

  • PerformanceCurves

    曲线.png

  • Technical Data

    Operating Pressure
    250bar
    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    10-2
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Flow Setting
    0.4 l/min. min., 22.7 l/min max.
    Flow Maintenance Accuracy
    0.37 to 1.85 l/min. settings ±20%
    1.89 to 5.63 l/min. settings ±15%
    5.68 to 22.71l/min. settings ±10%
    Temperature
    -40°F to +250°F(-40°C to +120°C)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar
  • File Download

    PDF File
  • ACCESSORIES

Contact Us