LPFR-10

PDF Download

Description

A cartridge-style adjustable pressure-compensated flow control valve

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    The valve maintains a constant flow rate from ③ regardless of load pressure changes in the system downstream of ③,or in the bypass leg at ②.The valve will pressure-compensate once a minimum pressure drop (determined by spring adjustment setting) is achieved from ① to ③ . This value will range from approximately 4.8 to 13.8 bar (70 to 200 psi). Bypass port ② may be fully pressurized.

    The cartridge may be adjusted to ±25% of nominal setting. At nominal setting, pressure drop is approximately 9 bar (130 psi).

    Flow out of priority port ③ may vary based on input flow amount, particularly with lower temperatures and increased fluid viscosities.

  • PerformanceCurves

    13-4.png

  • Technical Data

    Operating Pressure
    207Bar
    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    10-3
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Flow Setting
    low range: 1.9 to 9.5 lpm (0.5 to 2.5 gpm)
    Specify in 1.9 lpm (0.5 gpm) increments
    high range: 11.4 to 22.7 lpm (3.0 to 6.0 gpm)
    Specify in 3.8 lpm(1gpm) increments
    Temperature
    -40°F to +250°F(-40°C to +120°C)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar
  • File Download

    PDF File
  • ACCESSORIES

Contact Us