Up all
Pack up all
-
Technical Feature
OPERATION:
Flow is blocked from ① to ② until pressure increases to meet the selected valve setting, lifting the poppet from its seat and allowing relief flow through ② to tank. Pressure at ② is additive to the relief setting of the valve. The unique poppet design provides enhanced stability at all flows and pressures.
-
PerformanceCurves
-
Technical Data
350BarSee PRESSURE DROP VS.FLOW graph.08M-2Refer to "Cleanliness of Hydraulic Fluid"5 drops/min max. to 85% of nominal setting85% of crack pressure (crack pressure at 0.95 lpm /0.25 gpm)5 to 50 bar; preset 30 bar
30 to 100 bar ; preset 70 bar
50 to 210 bar ; preset 160 bar
100 to 350 bar ; preset 250 bar-40°F to +250°F(-40°C to +120°C)Mineral-based fluids with viscosities of 7.4 to 420 cSt.Steel & Ductile iron rated to 350bar -
File Download
PDF File -
ACCESSORIES