  • Technical Feature

    OPERATION:

    When pressure at V2 rises above the spring bias pressure, the check seat is pushed away
    from the piston and flow is allowed from V2 to C2 . When load pressure at C2 rises above the
    pressure setting, the direct-acting, differential area relief function is activated and flow is relieved
    from C2 to V2 . With pilot pressure at Pil
    the pressure setting is reduced in proportion to the
    stated ratio of the valve, until fully open with free-flow from C2 to V2
    The spring chamber is
    drained to V2
    and any back-pressure at V2 is additive to the pressure setting in all functions.

  • PerformanceCurves

    曲线.png

  • Technical Data

    Flow
    See PRESSURE DROP VS.FLOW graph.
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Max.Operating Pressure
    350Bar
    Internal Leakage
    5 drops/min . at nominal pressure
    Pilot Ratio
    4.2: 1
    Temperature
    -40°F to +250°F(-40°C to +120°C)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    Steel & Ductile iron rated to 350bar