LCOFA

PDF Download

Description

锥阀式液控关闭单向阀

SYMBOL

Contact Us

Up all

Pack up all

  • Technical Feature

    OPERATION:

    Pressure at ① overcomes the spring-bias poppet and allows free flow to ② . Flow in

    the opposite direction, from ② to ① ,is blocked by the poppet.

    When the required pilot pressure is achieved at ③ ,the poppet is held closed to block

    flow between ① and ② .The pilot piston area to poppet seat area ratio is 1.8 to 1.


  • PerformanceCurves

    LCOFA流量图.png

  • Technical Data

    Operating Pressure
    350bar
    Flow
    See PRESSURE DROP VS.FLOW graph.
    Cavity
    SUN T-2A
    Filtration
    Refer to "Cleanliness of Hydraulic Fluid"
    Internal Leakage
    2 drops/min. max. at 350bar
    Crack Pressures
    A=0.3bar
    B=1.0bar
    C=2.0bar
    D=3.5bar
    E=5.0bar
    F=7.0bar
    J=9.5bar
    Pilot Ratio
    1.8:1
    Temperature
    -40ºF to +250ºF(-40ºC to +120ºC)
    Fluids
    Mineral-based fluids with viscosities of 7.4 to 420 cSt.
    Body Material
    Steel & Ductile iron rated to 350bar
  • File Download

    PDF File
  • ACCESSORIES

Contact Us