- 2-Way 2-Position
- 2-Way 2-Position 3-Way 2-Position 4-Way 2-Position 4-Way 3-Position 5-Way 3-Position
Up all
Pack up all
- 
                            Technical FeatureOPERATION: When de-energized, the valve acts as a check valve, allowing flow from ① to ②, while 
 blocking flow from ② to ① .
 When energized, the poppet lifts to open the ② to ① flow path.Operation of Manual Override Option: The “J” Option includes a male 10-32 thread for a cable attachment. If a cable is 
 used, the internal valve spring may not provide enough force to overcome internal
 cable friction. An external means of returning the cable must be provided by the user.
- 
                            PerformanceCurves 
- 
                            Technical DataFlowSee PRESSURE DROP VS.FLOW graph.Cavity08-2FiltrationRefer to "Cleanliness of Hydraulic Fluid"Max.Operating Pressure207barInternal Leakage2 drops/min.max. at 207barTemperature-40°F to +212°F(-40°C to +100°C)Coil Duty RatingContinuous from 85% to 115% of nominal voltage.FluidsMineral-based fluids with viscosities of 7.4 to 420 cSt.Body Material6061-T6 aluminum alloy rated to 207bar, Steel & Ductile iron rated to 350bar
- 
                            File DownloadPDF File
- 
                            ACCESSORIES








 
        